EJOT® insulation support anchor DH individual components
Specification
-
Applications
- For fixing insulating material in the rear ventilated facade to all substrates
Benefits
- Prevents "quilt effect" (identations in the insulation) due to retrofitting of the washer
- Prevents gaping of the joints between the individual insulating panels at the joining edges
- Packing and handling volume is reduced by over 60% compared to one-part insulation support anchors
- Installation depth limiter guarantees defined installation, independent of the substrate
- Process reliable installation even with thick insulation boards
Notice
For the installation of two-ply insulation, additional stress plates are required. The practicability depends on the respective insulation properties and needs to be tested on site. Rotary hole drilling is obligatory in aerated concrete and perforated brick masonry.
-
Properties
- Requirement: 5 pcs. per m2
- Easy installation with no additional expansion element
- Parts can be positioned freely on the shaft
- All-purpose for all building materials
-
Technical specifications
Characteristic values
- Plate diameter: 90 mm
- Shaft diameter: 8 mm
- Drill bit diameter: 8 mm
- Drill hole depth ≥ t: 40 mm
- Embedment depth ≥ hv: 30 mm
- Point thermal transmittance χ: 0.0001 W/K
- Carrying capacity (pull over washer): 0.2 kN
Orderidentifier | Article Number | Material | Unit |
---|---|---|---|
DH-40 (one-part) | 8551906009 | Plastic | 300 |